FIR 1 - INSPECTION REPORT

Permit Holder: Camterra Resources, Inc Well Name/No: Gordon, Fannie I Permit: 28614
Lease Name: Gordon, Fannie I 1 Sec: 9 Twp: 8N Range 32W
GPS Well Location: Latitude: 35.3982 Longitude: -94.41261 Field: MASSARD  
Lease/Tank Battery: Latitude: 35.39825 Longitude: 94.41247 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway North 7th and Q Street
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 12' round x 7' h = 141 bbls (hole at 69" = 119 bbls)
2Fluids TankFiberglassOther Size 5 bbl tank at dehy unit
3Dehy UnitSteel Bolted   
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 28 Width: 28 Diameter: 0 Height: 0.75 Capacity (bbls): 105
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, well is equipped with H2S scavenger, dehy unit has several small leaks, dirt containment was damaged by recent flash flooding, chain link fencing was also damaged, location is used for Camterra equipment storage. Flood damage. No enforcement at this time.MP

Inspected by: DAYMON BLOUNT   Date:  9/5/2019 9:18:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: 9/13/2019
ADEQ referral:
Date of referral:  __________