FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: King, Ethel Permit: 17877
Lease Name: King, Ethel 1 Sec: 1 Twp: 8N Range 28W
GPS Well Location: Latitude: 35.40418 Longitude: -93.92368 Field: CECIL  
Lease/Tank Battery: Latitude: 35.404289 Longitude: 93.923681 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Pine Holler Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 12' D x 5' H = 100 bbls
2Fluids TankFiberglassOther Size 15 bbl waste oil tank with containment
3SeparatorSteel Welded   
4SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 21 Height: 2.66 Capacity (bbls): 164
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
FLT for temporarily abandoned well pump jack on the well head so casing test only the casing line pressure was 75 PSI with the fluid level @ 5079’ no plastic liner in the secondary containment no flow meter on location.

Inspected by: STEVEN PIKE   Date:  9/27/2022 4:09:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________