FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Denman Permit: 18621
Lease Name: Denman 1 Sec: 22 Twp: 9N Range 30W
GPS Well Location: Latitude: 35.44566 Longitude: -94.17489 Field: KIBLER-WILLIAMS  
Lease/Tank Battery: Latitude: 35.44661 Longitude: 94.17488 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Sharp Chapel Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 10' round x 7' h = 98 bbls
2Fluids TankFiberglassOther Size 15 bbl used oil tank with containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank with containment
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 15 Width: 15 Diameter: 0 Height: 3.5 Capacity (bbls): 140
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: Location has an operating compressor and an old non-working ajax compressor.
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, pump jack at wellhead, well is methanol injected, compressor is running, containment ring does not have a liner, several open plumbing lines coming from ground, containment for fresh oil and used oil tank is missing a plug, heavy oil and water are draining directly to ground, and running to edge of location. Operator contacted. No enforcement at this time.MP

Inspected by: DAYMON BLOUNT   Date:  9/25/2020 10:00:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________