FIR 1 - INSPECTION REPORT

Permit Holder: Bech Oil & Gas Well Name/No: Phillips Permit: 30753
Lease Name: Phillips 1 Sec: 3 Twp: 8N Range 31W
GPS Well Location: Latitude: 35.39702 Longitude: -94.27812 Field: SECTION TEN  
Lease/Tank Battery: Latitude: 35.40127 Longitude: 94.28596 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Catcher Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 6' round x 8' h = 40 bbls
2Fluids TankSteel WeldedOther Size 4' round x 7' h = 16 bbls
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 20 Height: 2 Capacity (bbls): 112
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Brush cleaned at site is to be removed as per phone conversation with Mr. Edsaon. No enforcement. MP Re-inspect of tank battery and equipment, as per follow up list, old barrels and equipment have been taken away, area around compressor has been cleaned, gravel containment around produced water tank is still too overgrown to get a proper measurement, gravel containment measurement are only estimated, due to excessive brier and thorn bushes.

Inspected by: DAYMON BLOUNT   Date:  9/23/2015 12:00:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: 9/30/2015
ADEQ referral:
Date of referral:  __________