FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Mathews, W Permit: 30759
Lease Name: Mathews, W 2 Sec: 2 Twp: 8N Range 27W
GPS Well Location: Latitude: 35.3901 Longitude: -93.83405 Field: AETNA  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Mathis Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 10' round x 8' h = 112 bbls
2Fluids TankFiberglassOther Size 15 bbl used oil tank inside containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank with containment
4SeparatorSteel Welded   
5SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 20 Width: 20 Diameter: 0 Height: 3.5 Capacity (bbls): 249
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
DPM, pump jack at well head, well is methanol injected, compressor is running, containment ring does not have a liner, moderate oil and grease inside containment, casing valve on well head is being repaired at time of inspection.

Inspected by: DAYMON BLOUNT   Date:  9/22/2015 12:56:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________