FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Fort Chaffee Federal Permit: 25750
Lease Name: Fort Chaffee Federal 2 Sec: 26 Twp: 8N Range 31W
GPS Well Location: Latitude: 35.34248 Longitude: -94.26704 Field: HOLLIS LAKE  
Lease/Tank Battery: Latitude: 35.34271 Longitude: 94.26678 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway Hwy 22 (inside old Chaffee property)
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 8' round x 8' h = 72 bbls
2SeparatorSteel Welded   
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 15 Width: 15 Diameter: 0 Height: 3 Capacity (bbls): 120
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, chart meter for Chaffee 3 on this location, plunger in wellhead, H2S scavenger has been disconnected, containment ring does not have a liner, moderate vegetation over location. NOTE: Location was completely under water due to heavy floods, location is back to producing with minimum damage.

Inspected by: DAYMON BLOUNT   Date:  9/10/2019 8:15:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________