FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Smith, R H Unit Permit: 22291
Lease Name: Smith, R H Unit 2 Sec: 19 Twp: 9N Range 26W
GPS Well Location: Latitude: 35.427 Longitude: -93.802 Field: AETNA  
Lease/Tank Battery: Latitude: 35.42678 Longitude: 93.80212 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway West Creek Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 16' round x 6' h = 215 bbls (holes at 38" = 113 bbls)
2Fluids TankFiberglassOther Size 15 bbl used oil tank
3SeparatorSteel Welded   
4SeparatorSteel Welded   
5SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 28 Width: 24 Diameter: 0 Height: 0.5 Capacity (bbls): 60
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, well is methanol injected, compressor is running, gravel containment is eroded and is nearly to ground level on N/W corner, used oil tank is on a platform without any containment, small amount of oil is dripping onto ground, clean location.

Inspected by: DAYMON BLOUNT   Date:  8/20/2020 2:16:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________