FIR 1 - INSPECTION REPORT

Permit Holder: Ironhorse Compression, Inc. Well Name/No: Hamilton D Permit: 27900
Lease Name: Hamilton D 1 Sec: 31 Twp: 8N Range 29W
GPS Well Location: Latitude: 35.32553 Longitude: -94.11925 Field: URSULA  
Lease/Tank Battery: Latitude: 35.32558 Longitude: 94.11934 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway Ursula Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 10' round x 8' h = 112 bbls
2SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 19 Height: 2.5 Capacity (bbls): 126
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, digital sales meter on location, compressor is running, bird netting is falling into tank, fluids inside tank are mostly waste oil, heavy amount of waste oil is running down plumbing and into containment, waste oil is also covering metal steps next to tank (possibly from a leaking hammer union or joint). NOTE: Pumper was on location and is going to return with oil dry. Operator (pumper) contacted by DB. No enforcement at this time.MP

Inspected by: DAYMON BLOUNT   Date:  7/8/2021 9:35:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: 7/12/2021
ADEQ referral:
Date of referral:  __________