FIR 1 - INSPECTION REPORT
Permit Holder:
Merit Energy Company, LLC
Well Name/No:
Casalman
Permit:
36118
Lease Name:
Casalman 3-35
Sec:
35
Twp:
9N
Range
28W
GPS Well Location:
Latitude:
35.42015
Longitude:
-93.93516
Field:
CECIL
Lease/Tank Battery:
Latitude:
35.42011
Longitude:
93.93492
County:
FRANKLIN
Entrance from nearest 911 address, public street or highway
Hwy 41
Status:
Completing
New not producing
Operating
Old not producing
Not found
Single well pad
Mutiple well pad
NA
Well equipment operational:
Equipment plumbed properly:
Excess equipment on lease:
Yes
No
NA
Yes
No
NA
Yes
No
Signs:
At lease entrance:
Yes
No
At tank battery:
Yes
No
NA
At well:
Yes
No
NA
Signage compliance:
Yes
No
No
Type
Construction
Size
Leaks
Remarks
1
Fluids Tank
Fiberglass
100
12' round x 5' h = 100 bbls
2
Fluids Tank
Fiberglass
Other Size
15 bbl used oil tank with containment
3
Fluids Tank
Other Types
Other Size
200 gal plastic used oil tank with containment
4
Separator
Steel Welded
5
Separator
Steel Welded
6
Separator
Steel Welded
7
Separator
Steel Welded
Tank Containment:
Earthen
Metal ring
Tank in tank
No Tanks
Other
Dimensions:
Length:
24
Width:
22
Diameter:
0
Height:
1
Capacity (bbls):
94
Capacity compliance:
Breaches/Erosion:
Excessive vegetation present:
Compliance agreement:
Yes
No
NA
Yes
No
NA
Yes
No
NA
Yes
No
NA
Containment Conditions:
Fluids Present:
Yes
No
Produced fluids
Storm water
Waste oil
NA
Other
Well Site Compressor:
Yes
No
Is it in compliance?
Yes
No
NA
Trash/Debris:
Yes
No
Use as storage area:
Yes
No
Unusual equipment:
Yes
No
Excessive erosion:
Yes
No
If yes to any, explain:
Entry Gate Present:
Yes
No
Gate locked on arrival:
Yes
No
Gate locked on departure:
Yes
No
Is spill or discharge of drilling, completion or produced fluids present:
Yes
No
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
Yes
No
NA
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing on tubing and casing, digital pipeline meter on location, well is methanol injected, compressor is running, East side of gravel containment has eroded to less than tank capacity, moderate vegetation around all equipment. NOTE: Pumper was on location and said he would contact Jamie Owen to repair containment. Operator contacted by DB. No enforcement at this time.MP
Inspected by:
DAYMON BLOUNT
Date:
7/6/2020 10:54:00 AM
Review for NNC or NOV:
Yes
No
If yes, check one
NNC
NOV
DNI
NA
Ref #:
Date:
7/7/2020
ADEQ referral:
Yes
No
Date of referral:
__________
Loading...