Permit Holder: Merit Energy Company, LLC Well Name/No: Wright Unit 4, Curtis - Humphreys, F A Permit: 18329
Lease Name: Wright Unit 4, Curtis - Humphreys, F A 1 Sec: 19 Twp: 9N Range 29W
GPS Well Location: Latitude: 35.44429 Longitude: -94.12924 Field: CECIL  
Lease/Tank Battery: Latitude: 35.44435 Longitude: 94.12912 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway Arbuckle Island Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 7' round x 7' h = 48 bbls
2SeparatorSteel Welded   
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 15 Height: 2.33 Capacity (bbls): 73
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
FIR is for a spill reported by XTO, heavy floods have had location under water, tank and containment were damaged. Location appears to be back to producing, tank and containment have been repaired, containment ring does not have a liner, clean location.

Inspected by: DAYMON BLOUNT   Date:  7/23/2019 3:14:00 PM