FIR 1 - INSPECTION REPORT

Permit Holder: Lyons & Lyons, Inc Well Name/No: Weatherl Permit: 27815
Lease Name: Weatherl 1-35 Sec: 35 Twp: 10N Range 29W
GPS Well Location: Latitude: 35.49528 Longitude: -94.05528 Field: CECIL  
Lease/Tank Battery: Latitude: 35.495315 Longitude: 94.055691 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Church Avenue
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 8’ D x 10’ H = 100 bbls
2Fluids TankSteel WeldedOther Size 200 gal steel oil tank
3Fluids TankOther TypesOther Size 4’ x 4’ x 4’ Plastic Tote = 11 bbls
4SeparatorSteel Welded   
5SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 28 Width: 15 Diameter: 0 Height: 1.25 Capacity (bbls): 94
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
H2S scavenger injected production well the secondary containment is no longer 1.5 times larger than the fluids tank numerous residual oily stains around the area. (RJS - no enforcement at this time)

Inspected by: STEVEN PIKE   Date:  7/20/2022 3:19:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________