FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Alexander, W Permit: 35982
Lease Name: Alexander, W 4-9 Sec: 9 Twp: 9N Range 29W
GPS Well Location: Latitude: 35.462 Longitude: -94.09284 Field: DYER  
Lease/Tank Battery: Latitude: 35.46237 Longitude: 94.09303 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Alexander Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 5' round x 6' h = 21 bbls
2SeparatorSteel Welded   
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 21 Height: 2.5 Capacity (bbls): 154
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: Compressor was moved prior to flooding.
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
FIR is for a spill reported by XTO. Heavy floods have caused major damage to location, meter run and upright separator were both damaged and plumbing pulled out of ground, produced water tank and containment damaged, produced water tank is broken loose and on ground outside of containment, both oil tanks washed away from location, Location is not back to producing, pump jack at wellhead, repairs are still being made. No enforcement at this time.MP

Inspected by: DAYMON BLOUNT   Date:  7/15/2019 3:23:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________