FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Lang Permit: 33552
Lease Name: Lang 4 Sec: 1 Twp: 8N Range 27W
GPS Well Location: Latitude: 35.38926 Longitude: -93.81708 Field: AETNA  
Lease/Tank Battery: Latitude: 35.38928 Longitude: 93.81721 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Hwy 309
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 12' round x 5' h = 100 bbls
2Fluids TankFiberglassOther Size 15 bbl used oil tank with containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank with containment
4Dehy UnitSteel Bolted   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 21 Height: 2.5 Capacity (bbls): 154
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, 2 WOC on location, well is methanol injected, compressor is not running, containment ring does not have a liner, moderate vegetation around wellhead and equipment.

Inspected by: DAYMON BLOUNT   Date:  7/11/2019 9:17:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________