FIR 1 - INSPECTION REPORT

Permit Holder: Lyons & Lyons, Inc Well Name/No: Stengel Permit: 25684
Lease Name: Stengel 1 Sec: 27 Twp: 8N Range 27W
GPS Well Location: Latitude: 35.33241 Longitude: -93.84968 Field: AETNA  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Sheep Farm Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 10' round x 7' h = 98 bbls
2Fluids TankOther TypesOther Size 11 bbl plastic tote with dirt containment
3Fluids TankOther TypesOther Size 11 bbl plastic tote with dirt containment
4SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 24 Width: 22 Diameter: 0 Height: 1.5 Capacity (bbls): 141
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: Heavy oil running across ground, several underground valves are leaking oil out onto location.
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, pipeline meter on location, well is chemical injected (foamer), compressor is running, hammer union at well head is leaking fluids onto ground, excessive vegetation over location and inside containment. No enforcement at this time.MP

Inspected by: DAYMON BLOUNT   Date:  6/19/2017 12:33:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________