FIR 1 - INSPECTION REPORT

Permit Holder: Hanna Oil and Gas Company Well Name/No: Reveley Permit: 48291
Lease Name: Reveley 14-16 Sec: 16 Twp: 6N Range 28W
GPS Well Location: Latitude: 35.19002 Longitude: -93.99006 Field: B-44 AREA  
Lease/Tank Battery: Latitude: 35.19016 Longitude: 92.990131 County: LOGAN  
Entrance from nearest 911 address, public street or highway Ferguson Valley Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 7' D x 7' H = 48 bbls
2SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 12 Height: 5.5 Capacity (bbls): 111
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Witness IOPT for new production well; the current line pressure for the casing is 405 PSI with the line pressure on the tubing was 226 PSI; the current flow is 517 MCF with the 24-hour flow rate was 219.5 MCFD; approximately 2" of storm water in the secondary containment; other than that a clean site.

Inspected by: STEVEN PIKE   Date:  5/4/2023 1:03:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________