FIR 1 - INSPECTION REPORT

Permit Holder: Rebel Producing, LLC Well Name/No: Clark, Spencer Permit: 14565
Lease Name: Clark, Spencer 1 Sec: 2 Twp: 18S Range 12W
GPS Well Location: Latitude: 33.17577 Longitude: -92.31627 Field: WINCHESTER  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: UNION  
Entrance from nearest 911 address, public street or highway
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
No Vessels Found For This Inspection

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 0 Height: 0 Capacity (bbls): 0
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Well has a pumping unit and it is bridled up to the polishing rod. The motor has been removed. No flow lines attached. The pumping tee is open on one side making the well unsecure. Needs a valve or plug. Well ID is present but is faded to an unreadable state. There is excess vegetation and 2 areas of excess tubing laying on the ground. Talked with the operator and he is addressing these issues. He is headed to get a plug for the pumping tee. GPS is 33.17564 -92.31622

Inspected by: GLEN OWENS   Date:  5/17/2023 10:04:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________