FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Kelley Permit: 34541
Lease Name: Kelley 2 Sec: 35 Twp: 7N Range 31W
GPS Well Location: Latitude: 35.23955 Longitude: -94.26786 Field: B-44 AREA  
Lease/Tank Battery: Latitude: 35.239542 Longitude: 94.268184 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway N. Main Street
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 12' D x 5' H = 100 bbls
2Fluids TankFiberglassOther Size 15 bbl waste oil tank with containment
3Fluids TankSteel WeldedOther Size 200 gal steel oil tank
4Fluids TankOther TypesOther Size 200 gal plastic tank
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 24 Height: 2.5 Capacity (bbls): 201
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing well, deteriorated plastic liner in the secondary containment, the compressor was not running during the inspection, otherwise a clean location.

Inspected by: STEVEN PIKE   Date:  3/3/2022 3:27:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________