FIR 1 - INSPECTION REPORT

Permit Holder: Lyons & Lyons, Inc Well Name/No: Storey Permit: 30636
Lease Name: Storey 1 Sec: 6 Twp: 7N Range 28W
GPS Well Location: Latitude: 35.30822 Longitude: -94.02107 Field: PETER PENDER  
Lease/Tank Battery: Latitude: 35.30814 Longitude: 94.02115 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Gammill Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 12' round x 7' h = 141 bbls
2Fluids TankOther TypesOther Size 4' x 4' x 4' plastic tote = 11 bbls
3Dehy UnitSteel Bolted   
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 24 Width: 24 Diameter: 0 Height: 1.25 Capacity (bbls): 128
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, plumbing at WOC and dehy is rotted and breaking apart, ball valve on upright separator is leaking gas and fluids onto ground, bird netting for produced water tank is gone, dirt containment has eroded to less than tank capacity. No enforcement at this time.MP (CV-19)

Inspected by: DAYMON BLOUNT   Date:  3/22/2021 9:31:00 AM