FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Crain, Erp Permit: 32865
Lease Name: Crain, Erp 3 Sec: 6 Twp: 9N Range 29W
GPS Well Location: Latitude: 35.47655 Longitude: -94.12004 Field: DYER  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Farm Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 11' round x 6' h = 102 bbls (holes at 5' 6" 93 bbls)
2Fluids TankFiberglassOther Size 15 bbl used oil tank with containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank with containment
4SeparatorSteel Welded   
5SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 15 Width: 15 Diameter: 0 Height: 3.5 Capacity (bbls): 140
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, pump jack at wellhead, compressor is running, containment ring does not have a liner, drain plugs for both used oil tanks have been removed, oil and fluids are draining onto ground, clean location.

Inspected by: DAYMON BLOUNT   Date:  3/21/2019 2:26:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________