FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Johnson, T E Permit: 30969
Lease Name: Johnson, T E 2 Sec: 20 Twp: 9N Range 28W
GPS Well Location: Latitude: 35.44434 Longitude: -93.99812 Field: CECIL  
Lease/Tank Battery: Latitude: 35.44408 Longitude: 93.99797 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Hwy 96
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 11' round x 6' h = 102 bbls
2Fluids TankFiberglassOther Size 15 bbl used oil tank inside containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank inside containment
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 21 Height: 2.66 Capacity (bbls): 164
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, well is methanol injected, compressor is not running, containment ring does not have a liner, wellhead and separators are showing heavy rust, clean location.

Inspected by: DAYMON BLOUNT   Date:  3/2/2020 3:08:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________