FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Tibbetts Permit: 19050
Lease Name: Tibbetts 1 Sec: 11 Twp: 8N Range 31W
GPS Well Location: Latitude: 35.38698 Longitude: -94.26861 Field: HOLLIS LAKE  
Lease/Tank Battery: Latitude: 35.38693 Longitude: 94.26881 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway McClure Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 16' round x 6' h = 215 bbls
2SeparatorSteel Welded   
3Fluids TankFiberglass210 10' round x 15' h with containment ring (belongs to Enable)
4SeparatorSteel Welded  belongs to Enable
5SeparatorSteel Welded  belongs to Enable

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 30 Height: 2.5 Capacity (bbls): 315
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: Compressor is running, belongs to Enable Kibler South gathering station.
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, pump jack at wellhead, containment ring does not have a liner, produced water tank is completely full, clean location shared with Enable Kibler South gathering station.

Inspected by: DAYMON BLOUNT   Date:  2/4/2021 9:40:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________