FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Wilson Permit: 34743
Lease Name: Wilson 4-35 Sec: 35 Twp: 9N Range 26W
GPS Well Location: Latitude: 35.40357 Longitude: -93.73096 Field: AETNA  
Lease/Tank Battery: Latitude: 35.40341 Longitude: 93.73104 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Jeannie Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 12' x 6'
2SeparatorSteel Welded   
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 25 Width: 26 Diameter: 0 Height: 2.5 Capacity (bbls): 290
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Fluid test conducted 2-28-23 Had to shoot casind through needle valve casing was 5 psi @ 2890 and tubing was @ 70 psi 2377. clean location.

Inspected by: HAYDEN SLAYTON   Date:  2/28/2023 5:05:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________