FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Smith, Leonard Permit: 33591
Lease Name: Smith, Leonard 2 Sec: 20 Twp: 9N Range 27W
GPS Well Location: Latitude: 35.44095 Longitude: -93.88177 Field: CECIL  
Lease/Tank Battery: Latitude: 35.44072 Longitude: 93.88162 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Hwy 96
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 12' round x 5' h = 100 bbls
2Fluids TankOther TypesOther Size 1500 gal plastic tank at compressor (belongs to Continental Shale)
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 21 Height: 2.5 Capacity (bbls): 154
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: Compressor is running and belongs to the Continental Shale, Burcham Heirs 3.
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Fluid level test conducted on 02/27 = Tubing - 4282' @ 54 PSI, Casing - 4126' @ 54 PSI, containment ring does not have a liner, compressor and plastic tank belong to Continental Shale Inc., clean location.

Inspected by: DAYMON BLOUNT   Date:  2/27/2020 12:53:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________