FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Martin, Ardell Permit: 35907
Lease Name: Martin, Ardell 1-26 Sec: 26 Twp: 5N Range 30W
GPS Well Location: Latitude: 35.07285 Longitude: -94.16988 Field: B-44 AREA  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: SCOTT  
Entrance from nearest 911 address, public street or highway Highway 71
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 11' round x 6' h = 102 bbls
2SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 24 Height: 2.33 Capacity (bbls): 188
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Production well, well was chemically injected, no longer plumbed, open top fluid tank has bird netting, the liner in the containment is deteriorated, very little storm water in containment, clean location.

Inspected by: STEVEN PIKE   Date:  2/25/2019 2:38:00 PM