FIR 1 - INSPECTION REPORT

Permit Holder: Dews Production LLC Well Name/No: Haydon, Mary Turner Permit: 17753
Lease Name: Haydon, Mary Turner 1 Sec: 25 Twp: 16S Range 27W
GPS Well Location: Latitude: 33.33598 Longitude: -93.8423 Field: FOUKE NORTH  
Lease/Tank Battery: Latitude: 33.33595 Longitude: -93.84217 County: MILLER  
Entrance from nearest 911 address, public street or highway
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Oil TankSteel Welded210  
2Oil TankSteel Welded210  
3Oil TankSteel Welded210  
4Oil TankSteel Welded210  
5Oil TankSteel Welded210  
6Gun BarrelSteel WeldedOther Size 12x4

Tank Containment:
Dimensions: Length: 100 Width: 30 Diameter: 0 Height: 3 Capacity (bbls): 1603
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Well presents with casing, tubing and rods. Flow line is not connected. There is no concrete slab or pumping unit. Well is secured with valves and bull plugs. Rods are secured with a clamp bolt. There is no sign posted on location. Well is inactive and shut in.

Inspected by: RONNIE KENNEDY   Date:  12/9/2020 9:27:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________