FIR 1 - INSPECTION REPORT

Permit Holder: L & L Energy Company Well Name/No: Hickey Permit: 29067
Lease Name: Hickey 1 Sec: 12 Twp: 4N Range 31W
GPS Well Location: Latitude: 35.02471 Longitude: -94.24194 Field: B-44 AREA  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway Elmore Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 0 Height: 0 Capacity (bbls): 0
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing well, well head, chart recorder and separator only, the lease road and well signs still have MaxExtract listed as the operator, there is no new chart or pens in the recorder, otherwise a clean location. RBDMS last production 09/2018. No enforcement at this time.MP

Inspected by: STEVEN PIKE   Date:  12/19/2019 1:38:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: 12/26/2019
ADEQ referral:
Date of referral:  __________