FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Hunter Permit: 35992
Lease Name: Hunter 5-19 Sec: 19 Twp: 9N Range 27W
GPS Well Location: Latitude: 35.4412 Longitude: -93.90869 Field: CECIL  
Lease/Tank Battery: Latitude: 35.44131 Longitude: 93.90876 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Idle Rock Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 12' round x 5' h = 100 bbls
2SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 20 Width: 20 Diameter: 0 Height: 1 Capacity (bbls): 71
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Fluid level test conducted on 12/15 = Tubing - 1977' @ 140 PSI, casing was tested several times, but could not get a valid fluid level, casing appears to possibly be full of trash, gravel containment has eroded down to dirt and is less than tank capacity, clean location. Refer to KL for enforcement.MP

Inspected by: DAYMON BLOUNT   Date:  12/15/2020 9:50:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: 12/18/2020
ADEQ referral: