FIR 1 - INSPECTION REPORT
Permit Holder:
Lyons & Lyons, Inc
Well Name/No:
Stengel
Permit:
25684
Lease Name:
Stengel 1
Sec:
27
Twp:
8N
Range
27W
GPS Well Location:
Latitude:
35.33241
Longitude:
-93.84968
Field:
AETNA
Lease/Tank Battery:
Latitude:
35.33257
Longitude:
93.85021
County:
FRANKLIN
Entrance from nearest 911 address, public street or highway
Sheep Farm Road
Status:
Completing
New not producing
Operating
Old not producing
Not found
Single well pad
Mutiple well pad
NA
Well equipment operational:
Equipment plumbed properly:
Excess equipment on lease:
Yes
No
NA
Yes
No
NA
Yes
No
Signs:
At lease entrance:
Yes
No
At tank battery:
Yes
No
NA
At well:
Yes
No
NA
Signage compliance:
Yes
No
No
Type
Construction
Size
Leaks
Remarks
1
Fluids Tank
Fiberglass
Other Size
10' round x 7' h = 98 bbls
2
Fluids Tank
Other Types
Other Size
4' x 4' x 4' plastic tote = 11 bbls (with dirt containment)
3
Separator
Steel Welded
Tank Containment:
Earthen
Metal ring
Tank in tank
No Tanks
Other
Dimensions:
Length:
24
Width:
21
Diameter:
0
Height:
1
Capacity (bbls):
90
Capacity compliance:
Breaches/Erosion:
Excessive vegetation present:
Compliance agreement:
Yes
No
NA
Yes
No
NA
Yes
No
NA
Yes
No
NA
Containment Conditions:
Fluids Present:
Yes
No
Produced fluids
Storm water
Waste oil
NA
Other
Well Site Compressor:
Yes
No
Is it in compliance?
Yes
No
NA
Trash/Debris:
Yes
No
Use as storage area:
Yes
No
Unusual equipment:
Yes
No
Excessive erosion:
Yes
No
If yes to any, explain:
Several underground plumbing lines are leaking, several areas of oil and fluids actively bubbling up trough gravel. Used oil filters have been thrown onto ground.
Entry Gate Present:
Yes
No
Gate locked on arrival:
Yes
No
Gate locked on departure:
Yes
No
Is spill or discharge of drilling, completion or produced fluids present:
Yes
No
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
Yes
No
NA
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, well is methanol injected, compressor is running, excessive vegetation inside containment and over location, dirt containment has eroded to less than tank capacity, large areas of location are covered with oil from active plumbing leaks. Operator contacted. Issues resolved.MP
Inspected by:
DAYMON BLOUNT
Date:
12/1/2020 1:29:00 PM
Review for NNC or NOV:
Yes
No
If yes, check one
NNC
NOV
DNI
NA
Ref #:
Date:
__________
ADEQ referral:
Yes
No
Date of referral:
__________
Loading...