FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Tankersley Permit: 37237
Lease Name: Tankersley 3-26 Sec: 26 Twp: 9N Range 29W
GPS Well Location: Latitude: 35.43564 Longitude: -94.04401 Field: CECIL  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: FRANKLIN  
Entrance from nearest 911 address, public street or highway Hwy 96
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass210 10' round x 15' h = 210 bbls
2Fluids TankFiberglassOther Size 15 bbl used oil tank with containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank with containment
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 28 Height: 3.5 Capacity (bbls): 384
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing on tubing and casing, pipeline meter on location, well is methanol injected, compressor is running, containment ring does not have a liner, clean location.

Inspected by: DAYMON BLOUNT   Date:  11/7/2017 1:56:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________