FIR 1 - INSPECTION REPORT

Permit Holder: MMGK Arkoma, LLC Well Name/No: Mitchell Permit: 35134
Lease Name: Mitchell 2 Sec: 4 Twp: 8N Range 32W
GPS Well Location: Latitude: 35.40367 Longitude: -94.41072 Field: MASSARD  
Lease/Tank Battery: Latitude: 35.40371 Longitude: 94.41162 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway Kelly Hwy (inside private salvage yard)
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 12' round x 10' h = 201 bbls
2Fluids TankFiberglassOther Size 5 bbl tank at dehy unit
3Dehy UnitSteel Bolted   
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 25 Width: 16 Diameter: 0 Height: 3 Capacity (bbls): 321
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, well is chemical injected (methanol and H2S scavenger), containment ring does have a liner, containment ring is completed rotted and starting to collapse, containment liner is coming through several rotted areas of metal ring, clean location behind chain link fencing. No enforcement at this time.MP

Inspected by: DAYMON BLOUNT   Date:  11/5/2021 10:43:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: 11/15/2021
ADEQ referral: