FIR 1 - INSPECTION REPORT

Permit Holder: Hanna Oil and Gas Company Well Name/No: Airport 94 Permit: 35493
Lease Name: Airport 94 1 Sec: 34 Twp: 8N Range 32W
GPS Well Location: Latitude: 35.33926 Longitude: -94.40011 Field: MASSARD  
Lease/Tank Battery: Latitude: 35.339152 Longitude: 94.400076 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway 31st Street and Phoenix Avenue
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 8' round x 8' h = 72 bbls (hole at 7' = 63 bbls)
2Fluids TankFiberglassOther Size 5 bbl tank at dehy unit
3Fluids TankSteel WeldedOther Size 200 gal steel methanol tank
4Dehy UnitSteel Bolted   
5SeparatorSteel Welded   
6SeparatorSteel Welded   
7SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 12 Height: 5 Capacity (bbls): 101
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
methanol injected production well from casing and tubing approximately 2” – 3” of storm water in the secondary containment the compressor was running during the inspection digital pipeline meter on location a clean site.

Inspected by: STEVEN PIKE   Date:  10/6/2022 3:09:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________