FIR 1 - INSPECTION REPORT

Permit Holder: Riverfront Exploration, LLC Well Name/No: Chancellor Permit: 23358
Lease Name: Chancellor 1 Sec: 31 Twp: 10N Range 29W
GPS Well Location: Latitude: 35.49305 Longitude: -94.11899 Field: DYER  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway East Line Street
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 10' round x 5' h = 70 bbls
2SeparatorSteel Welded   
3SeparatorSteel Welded   
4SeparatorSteel Welded   
5SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 20 Width: 18 Diameter: 0 Height: 1.25 Capacity (bbls): 80
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing. Compressor is running. Cattle guard at lease road entrance is broken and falling in. Lease road itself has large washouts. Clean location.

Inspected by: HAYDEN SLAYTON   Date:  10/23/2023 11:48:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________