FIR 1 - INSPECTION REPORT

Permit Holder: MMGK Arkoma, LLC Well Name/No: Williams, Bertha Permit: 14980
Lease Name: Williams, Bertha 1 Sec: 30 Twp: 8N Range 31W
GPS Well Location: Latitude: 35.35389 Longitude: -94.34151 Field: MASSARD  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway Massard Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 10' round x 8' h = 112 bbls
2Fluids TankFiberglassOther Size 10' round x 50" = 58 bbls
3Fluids TankFiberglassOther Size 8 bbl tank at dehy unit
4Dehy UnitSteel Bolted   
5SeparatorSteel Welded   
6SeparatorSteel Welded   
7SeparatorSteel Welded   
8     
9     
10     
11     
12     

Tank Containment:
Dimensions: Length: 9 Width: 23 Diameter: 0 Height: 2.33 Capacity (bbls): 258
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, AOG sales meter on location, location is chemical injected (methanol and H2S scavenger), compressor is not running, containment ring does have a liner, containment has several washouts, but liner appears to be in tact, clean location shared with Williams 2, behind chain link fencing.

Inspected by: DAYMON BLOUNT   Date:  10/18/2018 8:35:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________