FIR 1 - INSPECTION REPORT

Permit Holder: Unit Petroleum Company Well Name/No: Byars Permit: 33158
Lease Name: Byars 3-15 Sec: 15 Twp: 9N Range 30W
GPS Well Location: Latitude: 35.45677 Longitude: -94.17261 Field: KIBLER-WILLIAMS  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Sharp Chapel Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 11' round x 6' h = 102 bbls
2SeparatorSteel Welded   
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 24 Height: 2.33 Capacity (bbls): 188
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: Oil lines are leaking oil onto ground and off of skid plate.
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
DPM, plunger in well head, compressor is running, containment ring does have a liner, but is torn in several places, heavy oil in produced water tank.

Inspected by: DAYMON BLOUNT   Date:  10/16/2015 11:13:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________