FIR 1 - INSPECTION REPORT

Permit Holder: Riverfront Exploration, LLC Well Name/No: Nixon Permit: 18297
Lease Name: Nixon 1 Sec: 33 Twp: 8N Range 29W
GPS Well Location: Latitude: 35.32733 Longitude: -94.09116 Field: URSULA  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: SEBASTIAN  
Entrance from nearest 911 address, public street or highway HWY 252
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglass100 12' ROUND X 5' H = 100 BBLS
2SeparatorSteel Welded   
3SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 22 Height: 3 Capacity (bbls): 203
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing Compressor is running. Secondary containment ring has no liner and has storm water standing in it. Energy Transfer sale meter on site. Chart meter for this well has not been changed in along time digital meter on site. Otherwise clean location.

Inspected by: HAYDEN SLAYTON   Date:  1/9/2024 1:32:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________