FIR 1 - INSPECTION REPORT

Permit Holder: BHP Billiton Petroleum (Fayetteville), LLC Well Name/No: Waddle 11-17 Permit: 41177
Lease Name: Waddle 11-17 1-23H Sec: 23 Twp: 11N Range 17W
GPS Well Location: Latitude: 35.57751 Longitude: -92.76066 Field: B-43  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: VAN BUREN  
Entrance from nearest 911 address, public street or highway
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
No Vessels Found For This Inspection

Tank Containment:
Dimensions: Length: 0 Width: 0 Diameter: 0 Height: 0 Capacity (bbls): 0
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain: plumbed to the Waddle 11-17 # 2-23H
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
Well plugged 10-5-2017, production equipment removed, location in compliance, FINAL INSPECTION

Inspected by: CHRIS GREENE   Date:  1/5/2018 9:53:00 AM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________