FIR 1 - INSPECTION REPORT

Permit Holder: Merit Energy Company, LLC Well Name/No: Kirksey Permit: 35595
Lease Name: Kirksey 1 Sec: 33 Twp: 10N Range 29W
GPS Well Location: Latitude: 35.492 Longitude: -94.0821 Field: DYER  
Lease/Tank Battery: Latitude: 0 Longitude: 0 County: CRAWFORD  
Entrance from nearest 911 address, public street or highway Gin Town Road
Status:
Well equipment operational: Equipment plumbed properly: Excess equipment on lease:
Signs: At lease entrance:
At tank battery:
At well:
Signage compliance:

NoTypeConstructionSizeLeaksRemarks
1Fluids TankFiberglassOther Size 11' round x 7' h = 118 bbls (holes at 56" = 79 bbls)
2Fluids TankFiberglassOther Size 15 bbl used oil tank with containment
3Fluids TankOther TypesOther Size 200 gal plastic used oil tank (is flipped over inside containment)
4SeparatorSteel Welded   
5SeparatorSteel Welded   
6SeparatorSteel Welded   

Tank Containment:
Dimensions: Length: 15 Width: 15 Diameter: 0 Height: 3.5 Capacity (bbls): 140
Capacity compliance: Breaches/Erosion: Excessive vegetation present: Compliance agreement:
Containment Conditions: Fluids Present:
Well Site Compressor:
Is it in compliance?
Trash/Debris:
Use as storage area:
Unusual equipment:
Excessive erosion:
If yes to any, explain:
Entry Gate Present:
  Gate locked on arrival:
Gate locked on departure:
Is spill or discharge of drilling, completion or produced fluids present:
 
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
(If yes, complete FIR 5)
Compliance Summary Remarks:
APM, x2 on tubing and casing, pipeline meter on location, well is equipped with H2S scavenger, compressor is running, containment ring does not have a liner, location is being repaired from recent flood damages.

Inspected by: DAYMON BLOUNT   Date:  1/22/2016 2:14:00 PM
Review for NNC or NOV:
If yes, check one
Ref #: Date: __________
ADEQ referral:
Date of referral:  __________