FIR 1 - INSPECTION REPORT
Permit Holder:
Lyons & Lyons, Inc
Well Name/No:
USA
Permit:
22630
Lease Name:
USA 1-6
Sec:
6
Twp:
7N
Range
30W
GPS Well Location:
Latitude:
35.31518
Longitude:
-94.23148
Field:
EWING
Lease/Tank Battery:
Latitude:
35.31599
Longitude:
94.23129
County:
SEBASTIAN
Entrance from nearest 911 address, public street or highway
Fort Smith Blvd (inside Chaffee)
Status:
Completing
New not producing
Operating
Old not producing
Not found
Single well pad
Mutiple well pad
NA
Well equipment operational:
Equipment plumbed properly:
Excess equipment on lease:
Yes
No
NA
Yes
No
NA
Yes
No
Signs:
At lease entrance:
Yes
No
At tank battery:
Yes
No
NA
At well:
Yes
No
NA
Signage compliance:
Yes
No
No
Type
Construction
Size
Leaks
Remarks
1
Fluids Tank
Fiberglass
100
12' round x 5' h = 100 bbls
2
Fluids Tank
Other Types
Other Size
4' x 4' x 4' plastic tote
3
Fluids Tank
Other Types
Other Size
4' x 4' x 4' plastic tote
4
Separator
Steel Welded
Tank Containment:
Earthen
Metal ring
Tank in tank
No Tanks
Other
Dimensions:
Length:
20
Width:
20
Diameter:
0
Height:
1.5
Capacity (bbls):
107
Capacity compliance:
Breaches/Erosion:
Excessive vegetation present:
Compliance agreement:
Yes
No
NA
Yes
No
NA
Yes
No
NA
Yes
No
NA
Containment Conditions:
Fluids Present:
Yes
No
Produced fluids
Storm water
Waste oil
NA
Other
Well Site Compressor:
Yes
No
Is it in compliance?
Yes
No
NA
Trash/Debris:
Yes
No
Use as storage area:
Yes
No
Unusual equipment:
Yes
No
Excessive erosion:
Yes
No
If yes to any, explain:
Very heavy oil spills all around compressor. Oil is actively leaking from skid plate and plumbing lines, oil is running several feet away from compressor and into a ditch, oil going into ditch is being carried off of location and into wooded area.
Entry Gate Present:
Yes
No
Gate locked on arrival:
Yes
No
Gate locked on departure:
Yes
No
Is spill or discharge of drilling, completion or produced fluids present:
Yes
No
If yes, did spill or discharge of drilling, completion or produced fluids occur or travel off the well pad:
Yes
No
NA
(If yes, complete FIR 5)
Compliance Summary Remarks:
Producing, meter for USA 2-6 is on this location, compressor is not running, heavy oil issues over location, dirt containment for 2 plastic totes is almost eroded to ground level, location is inside secure area of Chaffee. Operator contacted. Issue resolved.MP
Inspected by:
DAYMON BLOUNT
Date:
1/15/2021 2:48:00 PM
Review for NNC or NOV:
Yes
No
If yes, check one
NNC
NOV
DNI
NA
Ref #:
Date:
1/29/2021
ADEQ referral:
Yes
No
Date of referral:
__________
Loading...